Contact us at: (310) 823-5491

While difficult to bond to, with the use of TRI's proprietary surface preparations and coating processes, Ready-to-Bond™ Etched FEP high voltage wire offers an excellent silastic bond.  Teflon tape wrapped cable, which is similar to FEP in dielectric strength and corona inception, is difficult to bond to because of its multiple spiral cross section, irregular surface and variations in diameter.

Benefits of extruded fluorinated ethylene propylene (FEP) insulated high voltage wire and cable:

  • Exceptional dielectric strength without the disadvantages common to equally rated silicone rubber insulated wire
  • Wire, cable assemblies and cable bundles have much smaller diameter than silicone wire and, therefore, take up substantially less volume while also having a smaller bend radius allowing the designer to better utilize the space within the system
  • Low DC corona inception, particularly after numerous temperature cycles
  • Excellent durability and resistance to dielectric/cooling fluid degradation
  • Inert when exposed to most industrial solvents and chemicals
  • Meet NASA low outgassing TML and CVCM levels 
  • Not prone to "pin-holing" and high voltage punch-through when the cable surface is abraded or when strands break during in-field use 
  • More resistant to damage when making contact with sharp edges, although this should be avoided when designing high voltage systems

FEP cable should not only be considered for use in cable assemblies, but as high voltage hook up wire within encapsulated high voltage power supplies, TWTs and transformers. 

Note: Pre-conditioning of FEP wire or cable is recommended because FEP insulation will shrink when exposed to temperature cycling. Pre-conditioning should be conducted in an air circulating oven at 204°C (400°F) for one hour. Pre-conditioning should only be performed on cut lengths prior to stripping and any termination procedure. No attempt should be made to condition wire or cable in bulk form or while spooled.

Operating Temperature

-55 to 125ºC

Unit of Measure
Items
FEP

Etched High Voltage Wire

FEP

Etched High Voltage Wire

FEP

Etched High Voltage Wire

FEP

Etched High Voltage Wire

FEP

Etched High Voltage Wire
Conductor Gauge N/A 28 AWG N/A 29 AWG N/A 20 AWG N/A 18 AWG N/A 20 AWG
Conductor Strands N/A 19/40 N/A 51/46 N/A 19/32 N/A 19/30 N/A 19/32
Conductor Plating N/A Silver Plated N/A Silver Plated N/A N/A Tin Plated N/A Silver Plated
Conductor Material N/A Copper
Material N/A N/A N/A Silver Plated Copper N/A N/A
Insulator Material N/A FEP
Conductor Diameter N/A 0.040 in N/A 0.025 in N/A 0.080 in N/A 0.080 in N/A 0.060 in
Default Color1 N/A Natural
Overall Diameter N/A 0.040 in N/A 0.025 in N/A 0.080 in N/A 0.080 in N/A 0.060 in
Length N/A
Silicone Coated N/A No
Jacketed N/A No
Etched N/A Yes
Nomex ® Jacketed N/A No N/A No N/A N/A No N/A No
Twisted Pair N/A No N/A No N/A N/A No N/A No
Twisted Shielded Pair N/A No N/A No N/A N/A No N/A No
Operating Temperature N/A -55 to 125 ºC
Standard/Non-Standard2 N/A Standard Part
Silicone Coated Part Number N/A N/A N/A N/A 178-9669 N/A
Nomex ® Jacketed Silicone Coated Part Number N/A N/A N/A N/A 178-9644 N/A
Nomex ® Jacketed Etched Part Number N/A
Silver Plated Conductor Part Number N/A
Voltage Rating N/A 5 kVDC N/A 5 kVDC N/A 15 kVDC N/A 21 kVDC N/A 10 kVDC
Wire Type N/A N/A N/A FEP ETCHED N/A N/A
  • 1 Other colors available upon request.
  • 2 Non-standard parts will have longer lead times and potentially higher pricing. Please contact Teledyne Reynolds Engineering department to determine feasibility for use in your application.