Print Back
  1. Capacitance Tolerance:- ± 10%
  2. Dissipation Factor:- 0.005 Max. at 25°C, 1 kHZ
  3. Insulation Resistance:-
      4000 MΩ*µF at25°C, need not exceed 100GΩ
      25 MΩ*µF at125°C, need not exceed 1GΩ
  4. Dielectric withstanding voltage:-
      2.5 kV rated
      3.75 kV burn-in for 2 hours at 100°C
      5.0 kV proof for 5 seconds
  5. Mylar wrapped, epoxy end capped
  6. Black dot indicates outer foil
  7. Wire leads are AWG 18 solder coated copper
  8. Safety:- Capacitors are shipped with leads shorted

We also manufacture military quality standard and custom designed Spark Gaps and Voltage Multipliers. If you have a corona test requirement but lack the necessary test equipment, we offer AC and DC corona testing services including a test report. Call for information concerning these services.

Unit of Measure

Specifications

Capacitance

N/A 100 nF

Capacitance Tolerance

N/A ±10%

Length

N/A 2.19 in55.6 mm

Width

N/A 1.36 in34.5 mm

Thickness

N/A 0.24 in6.1 mm

Dissipation Factor

N/A 0.005 Max. at 25°C, 1 kHZ

Dielectric Withstanding Voltage

N/A 2.5 kV rated 3.75 kV burn-in for 2 hours at 100°C 5.0 kV proof for 5 seconds
Standard/Non-Standard1 N/A Standard Part

Voltage Rating

N/A 2.5 kVDC

Cable Preparation

Insulation Resistance

N/A 25 MΩ*µF at125°C, need not exceed 1GΩ 4000 MΩ*µF at25°C, need not exceed 100GΩ