  1. Capacitance Tolerance: ±10%
  2. Dissipation Factor: .005 Max. at 25°C, 1 kHZ
  3. Insulation Resistance:
      4000 MΩ*µF at25°C, need not exceed 100GΩ
      25 MΩ*µF at 125°C, need not exceed 1GΩ
  4. Dielectric withstanding voltage:
      5.0 kV rated
      7.5 kV burn-in for 2 hours at 100°C
      10.0 kV proof for 5 seconds
  5. Mylar wrapped, epoxy endcapped
  6. Black dot indicates outer foil
  7. Wire leads are AWG 18 solder coated copper
  8. Safety: Capacitors are shipped with leads shorted

We also manufacture military quality standard and custom designed Spark Gaps and Voltage Multipliers. If you have a corona test requirement but lack the necessary test equipment, we offer AC and DC corona testing services including a test report. Call for information concerning these services.

Unit of Measure

Specifications

Capacitance

N/A 50 nF

Capacitance Tolerance

N/A ±10%

Length

N/A 2.56 in65.0 mm

Width

N/A 1.62 in41.1 mm

Thickness

N/A 0.26 in6.6 mm

Dissipation Factor

N/A 0.005 Max. at 25°C, 1 kHZ

Dielectric Withstanding Voltage

N/A 10.0 kV proof for 5 seconds 5 kV rated 7.5 kV burn-in for 2 hours at 100°C
Standard/Non-Standard1 N/A Standard Part

Voltage Rating

N/A 5 kVDC

Cable Preparation

Insulation Resistance

N/A 25 MΩ*µF at125°C, need not exceed 1GΩ 4000 MΩ*µF at25°C, need not exceed 100GΩ
  • 1 Non-standard parts will have longer lead times and potentially higher pricing. Please contact Teledyne Reynolds Engineering department to determine feasibility for use in your application.