| Series | N/A 1807 | 
| Number of Contacts | N/A 7 | 
| Voltage Rating | N/A 15 kVDC | 
| Altitude Rating | N/A 70,000 ft | 
| Operating Temperature | N/A -55 to 125 ºC | 
| Current Rating | N/A 7.5 A | 
| Insulator Material | N/A Plastic | 
| Coupling Style | N/A Bayonet | 
| Wire Insulation | N/A FEP | 
| Braid Termination | N/A Clamp | 
| Test Voltage at 70,000 ft | N/A 22 kVDC | 
| Panel Mounting Torque | N/A 84 ± 2 in.lb | 
| Pressure Differential Rating | N/A Sealed for 1 ATM | 
| Maximum Leak Rate (Helium) | N/A 1 X 10-6 cc/sec | 
| Panel Mounting Style | N/A Rear Mount | 
| Assembly | N/A Receptacle Bag Assembly | 
| Cable Assembly Length1 | N/A All cable assembly cable lengths are to be specified in inches only. For example, to order part number 178-6027 with a cable length of 10 feet 8 inches the cable assembly part number would be specified as 178-6027-128N. | 
| Manufacturing Notes | N/A Contact Teledyne Reynold's Engineering to discuss custom designs. Product numbers and specs subject to change without notice. Products listed represent only a small selection of Teledyne Reynold's products please visit www.teledynereynolds.com for the most up to date product information. | 