Note 1: Add .025 inch/0.63mm to diameter over silicone coated insulation to arrive at diameter over the Nomex jacket.
Note 2: To prevent fraying of the Nomex jacket, apply a small band of epoxy resin about 1 inch from the end of the Nomex jacket. Mow to cure and trim back the Nomex to the leading edge of the cured epoxy. Alternative methods are shrink sleeving or silicone rubber sleeving in place of the epoxy resin.
With the addition of a Nomex woven jacket over the silicone coated surface of the FEP insulation, the cable offers excellent abrasion resistance.
Operating Temperature
-55 to +125 ºC
Part Number |
Item Name |
Conductor Gauge |
Conductor Strands |
Conductor Plating |
Conductor Diameter |
Diameter Over Silicone Coating |
Conductor Material |
Voltage Rating |
Wire Type |
---|---|---|---|---|---|---|---|---|---|
178-5597 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 16 AWG | N/A 19/29 | N/A Silver Plated | N/A 0.056 in0.095 in1.430 mm | N/A 0.095 in2.410 mm | N/A Copper | N/A 12 kVDC | N/A |
178-5789 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 24 AWG | N/A 19/36 | N/A Silver Plated | N/A 0.025 in0.060 in0.640 mm | N/A 0.060 in1.520 mm | N/A Copper | N/A 18 kVDC | N/A |
178-5724 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 22 AWG | N/A 19/34 | N/A Silver Plated | N/A 0.031 in0.070 in0.800 mm | N/A 0.070 in1.780 mm | N/A Copper | N/A 20 kVDC | N/A |
178-8881 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 20 AWG | N/A 19/32 | N/A Silver Plated | N/A 0.039 in0.090 in1.010 mm | N/A 0.090 in2.290 mm | N/A Copper | N/A 25 kVDC | N/A |
178-9554 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 20 AWG | N/A 19/32 | N/A Silver Plated | N/A 0.039 in0.110 in1.010 mm | N/A 0.110 in2.790 mm | N/A Copper | N/A 30 kVDC | N/A S/C FEP |
178-7739 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 26 AWG | N/A 19/38 | N/A Tin Plated | N/A 0.060 in1.524 mm | N/A 0.060 in1.524 mm | N/A Copper | N/A 18 kVDC | N/A |
178-7740 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 22 AWG | N/A 19/34 | N/A Tin Plated | N/A 0.070 in1.778 mm | N/A 0.070 in1.778 mm | N/A Copper | N/A 20 kVDC | N/A |
178-7741 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 20 AWG | N/A 19/32 | N/A Tin Plated | N/A 0.090 in2.286 mm | N/A 0.090 in2.286 mm | N/A Copper | N/A 25 kVDC | N/A |
178-7742 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 20 AWG | N/A 19/32 | N/A Tin Plated | N/A 0.110 in2.794 mm | N/A 0.110 in2.794 mm | N/A Copper | N/A 30 kVDC | N/A |
178-8357 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 24 AWG | N/A 19/36 | N/A Tin Plated | N/A 0.060 in1.524 mm | N/A 0.060 in1.524 mm | N/A Copper | N/A 18 kVDC | N/A |
178-9644 | N/A Silicone Coated FEP Cable with Nomex® Woven Protective Jacket | N/A 18 AWG | N/A 19/30 | N/A Tin Plated | N/A 0.090 in2.286 mm | N/A 0.090 in2.286 mm | N/A Copper | N/A 21 kVDC | N/A |