Print Back
Unit of Measure

Specifications

Series

1807

Number of Contacts

7

Voltage Rating

15 kVDC

Altitude Rating

70,000 ft

Operating Temperature

-55 to 125 ºC

Current Rating

7.5 A

Insulator Material

Silicone

Coupling Style

Threaded

Threaded Coupling Available

Yes

Wire Type

Non-Shielded

Wire Insulation

FEP

Braid Termination

Clamp

Test Voltage at 70,000 ft

22 kVDC

Accomodates Wire Diameter

0.080 in2.032 mm

Mating Compatibility

Mates all series 1807 threaded receptacles

Assembly

Double-Ended Plug Cable Assembly

END #1

167-9693

END #2

167-9693

Sealed Receptacle

No
Standard/Non-Standard1 Nonstandard Part
Cable Assembly Length2 All cable assembly cable lengths are to be specified in inches only. For example, to order part number 178-6027 with a cable length of 10 feet 8 inches the cable assembly part number would be specified as 178-6027-128N.

Manufacturing Notes

Contact Teledyne Reynold's Engineering to discuss custom designs. Product numbers and specs subject to change without notice. Products listed represent only a small selection of Teledyne Reynold's products please visit www.teledynereynolds.com for the most up to date product information.

Coupling Nut Properties

Coupling Nut Material

Aluminum

Coupling Nut Finish

Nickel

Contact Properties

Contact Material

Brass

Contact Finish

Gold

Application

N/A 15 kVDC
Rated at 15 kVDC at altitudes up to 70,000 feet, these 7 pin connectors are ideal for higher power TWTs and RADAR power supplies.

Wire Specifications

Part #

167-9543

Operating Voltage

21 kVDC

Conductor AWG

20

Conductor Strands

19/32

Conductor Plating

TPC

Insulation Material

FEP

Insulator Diameter

0.080 in2.03 mm
  • 1 Non-standard parts will have longer lead times and potentially higher pricing. Please contact Teledyne Reynolds Engineering department to determine feasibility for use in your application.
  • 2 (Mentioned in the image by **)