Contact us at: (310) 823-5491
High Voltage Coaxial/Shielded Cable
These coaxial and shielded cables have been used in both military and industrial high voltage applications including Radar, ECM systems, power supplies and instrumentation. Many of the cables have controlled impedance. Figures for inductance and loop resistance (shield coupled to center conductor) are available upon request.

167-2669 and 178-8793 cables have controlled impedance, inductance and capacitance for fast response times and are used extensively to connect Exploding Bridge wire Detonators (EBW) to a Capacitor Discharge Unit (CDU).

Cable 178-5065 has foam insulation, giving lower capacitance and higher impedance. It has been used in cockpit displays.

Reynolds connectors are available for use with all cable types shown to complete your high voltage interconnection requirements.

Pre-conditioning of FEP wire or cable is recommended because FEP insulation will shrink when exposed to temperature cycling. Pre-conditioning should be conducted in an air circulating oven at 204ºC (400ºF) for one hour. Pre-conditioning should only be performed on cut lengths prior to stripping and any termination procedure. No attempt should be made to condition wire or cable in bulk form or while spooled.

While ordering, Use part number and specify length in feet.

Operating Temperature
-55 to +125 ºC

Unit of Measure
Items
High Voltage Coaxial/shielded Cable

High Voltage Coaxial/Shielded Cable

High Voltage Coaxial/shielded Cable

High Voltage Coaxial/Shielded Cable

High Voltage Coaxial/shielded Cable

High Voltage Coaxial/Shielded Cable

High Voltage Coaxial/shielded Cable

High Voltage Coaxial/Shielded Cable

High Voltage Coaxial/shielded Cable

High Voltage Coaxial/Shielded Cable
Conductor Gauge N/A 26 AWG N/A 16 AWG N/A 22 AWG N/A 22 AWG N/A 20 AWG
Conductor Strands N/A 19/38 N/A 18/29 N/A 19/34 N/A 19/34 N/A 19/32
Conductor Plating N/A Silver Plated N/A Tin Plated N/A Silver Plated N/A Silver Plated N/A Tin Plated
Conductor Diameter N/A 0.019 in0.095 in N/A 0.059 in0.195 in N/A 0.031 in0.125 in N/A 0.031 in0.145 in N/A 0.039 in0.220 in
Overall Diameter N/A 0.095 in N/A 0.195 in N/A 0.125 in N/A 0.145 in N/A 0.220 in
Insulator Material N/A FEP N/A PE N/A FEP N/A FEP N/A FEP
Diameter Over Insulation N/A 0.050 in N/A 0.118 in N/A 0.080 in N/A 0.100 in N/A 0.150 in
Shielding Strands N/A 36 AWG
Shielding Strand Plating N/A Silver Plated Copper N/A Tin Plated Copper N/A Silver Plated Copper N/A Silver Plated Copper N/A Tin Plated Copper
Shielding Layers N/A 1
Diameter Over Shield N/A 0.075 in N/A 0.150 in N/A 0.100 in N/A 0.120 in N/A 0.180 in
Jacket Material N/A FEP N/A PE N/A FEP N/A FEP N/A FEP
Diameter Over Jacket N/A 0.095 in N/A 0.195 in N/A 0.125 in N/A 0.145 in N/A 0.220 in
Impedance N/A 46 Ω N/A 31 Ω N/A 43 Ω N/A 50 Ω N/A
Attenuation at 400 MHz N/A 25 db/100 ft N/A 16 db/100 ft N/A 10.6 db/100 ft N/A N/A
Capacitance at 1k Hz N/A 33.7 pF/ft N/A 48 pF/ft N/A 31 pF/ft N/A 29.3 pF/ft N/A 26 pF/ft
Jacket Color N/A
Default Color N/A Natural N/A Red N/A Natural N/A Natural N/A Natural
Nomex Jacketed N/A Yes
Silicone Coated N/A No
Etched N/A No
Operating Temperature N/A -55 to 125 ºC
Wire Type N/A Shielded
Standard/Non-Standard1 N/A Standard Part
Nomex ® Jacketed Silicone Coated Part Number N/A N/A N/A 178-9610 N/A N/A
Nomex ® Jacketed N/A No
Twisted Pair N/A No
Twisted Shielded Pair N/A No
Conductor Material N/A Copper
Voltage Rating N/A 18 kVDC N/A 20 kVDC N/A 22 kVDC N/A 25 kVDC N/A 40 kVDC
Wire Insulation N/A "L" N/A "L" N/A 0.080 "L" N/A 0.100 "L" N/A
  • 1 Non-standard parts will have longer lead times and potentially higher pricing. Please contact Teledyne Reynolds Engineering department to determine feasibility for use in your application.