Contact us at: (310) 823-5491
Unit of Measure

Specifications

Series

N/A 1807

Number of Contacts

N/A 7

Voltage Rating

N/A 15 kVDC

Altitude Rating

N/A 70,000 ft

Operating Temperature

N/A -55 to 125 ºC

Current Rating

N/A 7.5 A

Insulator Material

N/A Plastic

Coupling Style

N/A Bayonet

Wire Insulation

N/A FEP

Braid Termination

N/A Clamp

Test Voltage at 70,000 ft

N/A 22 kVDC

Panel Mounting Torque

N/A 84 ± 2 in.lb

Pressure Differential Rating

N/A Sealed for 1 ATM

Maximum Leak Rate (Helium)

N/A 1 X 10-6 cc/sec

Panel Mounting Style

N/A Rear Mount

Assembly

N/A Receptacle Bag Assembly
Cable Assembly Length1 N/A All cable assembly cable lengths are to be specified in inches only. For example, to order part number 178-6027 with a cable length of 10 feet 8 inches the cable assembly part number would be specified as 178-6027-128N.

Manufacturing Notes

N/A Contact Teledyne Reynold's Engineering to discuss custom designs. Product numbers and specs subject to change without notice. Products listed represent only a small selection of Teledyne Reynold's products please visit www.teledynereynolds.com for the most up to date product information.

Coupling Nut Properties

Coupling Nut Material

N/A Aluminum

Coupling Nut Finish

N/A Nickel

Contact Properties

Contact Material

N/A BeCu

Contact Finish

N/A Gold with CRES Hood
  • 1 (Mentioned in the image by **)