167-2669 and 178-8793 cables have controlled impedance, inductance and capacitance for fast response times and are used extensively to connect Exploding Bridge wire Detonators (EBW) to a Capacitor Discharge Unit (CDU).
Cable 178-5065 has foam insulation, giving lower capacitance and higher impedance. It has been used in cockpit displays.
Reynolds connectors are available for use with all cable types shown to complete your high voltage interconnection requirements.
Pre-conditioning of FEP wire or cable is recommended because FEP insulation will shrink when exposed to temperature cycling. Pre-conditioning should be conducted in an air circulating oven at 204ºC (400ºF) for one hour. Pre-conditioning should only be performed on cut lengths prior to stripping and any termination procedure. No attempt should be made to condition wire or cable in bulk form or while spooled.
While ordering, Use part number and specify length in feet.
Operating Temperature
-55 to +125 ºC
Items |
167-2896 High Voltage Coaxial/Shielded Cable |
167-2669 High Voltage Coaxial/Shielded Cable |
167-9346 High Voltage Coaxial/Shielded Cable |
167-8726 High Voltage Coaxial/Shielded Cable |
167-9785 High Voltage Coaxial/Shielded Cable |
|||||
Conductor Gauge | N/A 26 AWG | N/A 16 AWG | N/A 22 AWG | N/A 22 AWG | N/A 20 AWG | |||||
Conductor Strands | N/A 19/38 | N/A 18/29 | N/A 19/34 | N/A 19/34 | N/A 19/32 | |||||
Conductor Plating | N/A Silver Plated | N/A Tin Plated | N/A Silver Plated | N/A Silver Plated | N/A Tin Plated | |||||
Conductor Diameter | N/A 0.019 in0.095 in | N/A 0.059 in0.195 in | N/A 0.031 in0.125 in | N/A 0.031 in0.145 in | N/A 0.039 in0.220 in | |||||
Overall Diameter | N/A 0.095 in | N/A 0.195 in | N/A 0.125 in | N/A 0.145 in | N/A 0.220 in | |||||
Insulator Material | N/A FEP | N/A PE | N/A FEP | N/A FEP | N/A FEP | |||||
Diameter Over Insulation | N/A 0.050 in | N/A 0.118 in | N/A 0.080 in | N/A 0.100 in | N/A 0.150 in | |||||
Shielding Strands | N/A 36 AWG | |||||||||
Shielding Strand Plating | N/A Silver Plated Copper | N/A Tin Plated Copper | N/A Silver Plated Copper | N/A Silver Plated Copper | N/A Tin Plated Copper | |||||
Shielding Layers | N/A 1 | |||||||||
Diameter Over Shield | N/A 0.075 in | N/A 0.150 in | N/A 0.100 in | N/A 0.120 in | N/A 0.180 in | |||||
Jacket Material | N/A FEP | N/A PE | N/A FEP | N/A FEP | N/A FEP | |||||
Diameter Over Jacket | N/A 0.095 in | N/A 0.195 in | N/A 0.125 in | N/A 0.145 in | N/A 0.220 in | |||||
Impedance | N/A 46 Ω | N/A 31 Ω | N/A 43 Ω | N/A 50 Ω | N/A | |||||
Attenuation at 400 MHz | N/A 25 db/100 ft | N/A 16 db/100 ft | N/A 10.6 db/100 ft | N/A | N/A | |||||
Capacitance at 1k Hz | N/A 33.7 pF/ft | N/A 48 pF/ft | N/A 31 pF/ft | N/A 29.3 pF/ft | N/A 26 pF/ft | |||||
Jacket Color | N/A | |||||||||
Default Color | N/A Natural | N/A Red | N/A Natural | N/A Natural | N/A Natural | |||||
Nomex Jacketed | N/A Yes | |||||||||
Silicone Coated | N/A No | |||||||||
Etched | N/A No | |||||||||
Operating Temperature | N/A -55 to 125 ºC | |||||||||
Wire Type | N/A Shielded | |||||||||
Standard/Non-Standard1 | N/A Standard Part | |||||||||
Nomex ® Jacketed Silicone Coated Part Number | N/A | N/A | N/A 178-9610 | N/A | N/A | |||||
Nomex ® Jacketed | N/A No | |||||||||
Twisted Pair | N/A No | |||||||||
Twisted Shielded Pair | N/A No | |||||||||
Conductor Material | N/A Copper | |||||||||
Voltage Rating | N/A 18 kVDC | N/A 20 kVDC | N/A 22 kVDC | N/A 25 kVDC | N/A 40 kVDC | |||||