The spark gaps are available in a DC breakdown voltage range from 90 to 2000 volts except for the half and quarter sizes which are limited to an upper limit of 1000 and 500 volts respectively. Note: Voltages are available thru 1650V on MCQ and thru 2000V on MCH series provided adequate over-potting is utilized by the customer. Units normally stocked are as follows. Other breakdown voltages are available on request.
Items |
MCH-0230 Micro-Arc Series |
MCH-0350 Micro-Arc Series |
MCH-0500 Micro-Arc Series |
MCH-0800 Micro-Arc Series |
MCH-1000 Micro-Arc Series |
|||||
Series | N/A Micro-Arc Series | |||||||||
Diameter | N/A 0.187 in | |||||||||
Surge Current | N/A 1000 A | |||||||||
DC Breakdown Voltage at 100V/sec | N/A 196 to 264 V | N/A 298 to 402 V | N/A 425 to 575 V | N/A 680 to 920 V | N/A 850 to 1150 V | |||||
Impulse Breakdown at 10kV/usec | N/A <1100 | N/A <1200 | N/A <1300 | N/A <1800 | N/A <2100 | |||||
Standard/Non-Standard1 | N/A Standard Part | |||||||||
|