Print Back
The convenient physical size of the Milli-Arc series of spark gaps and their 10,000 ampere (8 x 20 usec waveshape) discharge capability make this series the most suitable for general purpose transient protection. They also may be used for energy release in exploding bridgewire applications and in various vacuum tube grid circuits for tube arc protection. Insulation resistance is greater than 109ohms and capacitance is less than 2 pF. Milli-Arc tubes are available in breakdown voltages from 90 to 4500 volts (MLH), 8500 volts (MLF). Units normally stocked are as follows. Other breakdown voltages available on request.
MCH
Milli-Arc-Series-Dim-Drawin
Unit of Measure
Items MCH
MLH-0090
Milli-Arc Series
MCH
MLH-0230
Milli-Arc Series
MCH
MLH-0350
Milli-Arc Series
MCH
MLH-0500
Milli-Arc Series
MCH
MLH-0800
Milli-Arc Series
Series N/A Milli-Arc Series
Diameter N/A 0.312 in
Surge Current N/A 10000 A
DC Breakdown Voltage at 100V/sec N/A 72 to 108 V N/A 196 to 264 V N/A 298 to 402 V N/A 425 to 575 V N/A 680 to 920 V
Impulse Breakdown at 10kV/usec N/A <1000 N/A <1100 N/A <1200 N/A <1300 N/A <1800
Standard/Non-Standard1 N/A Standard Part
  • 1 Non-standard parts will have longer lead times and potentially higher pricing. Please contact Teledyne Reynolds Engineering department to determine feasibility for use in your application.