Print Back
  1. Capacitance Tolerance:-  ± 10%
  2. Dissipation Factor:- 0 .005 Max. at 25°C, 1 kHZ
  3. Insulation Resistance:-
       4000 MΩ*µF at25°C, need not exceed 100GΩ
       25 MΩ*µF at125°C, need not exceed 1GΩ
  4. Dielectric withstanding voltage:-
       12.5 kV rated
       15 kV burn-in for 2 hours @ 100°C
       17.5 kV proof for 5 seconds
  5. Mylar wrapped, epoxy endcapped
  6. Black dot indicates outer foil
  7. Wire leads are AWG 18 solder coated copper
  8. Safety:- Capacitors are shipped with leads shorted
We also manufacture military quality standard and custom designed Spark Gaps and Voltage Multipliers. If you have a corona test requirement but lack the necessary test equipment, we offer AC and DC corona testing services including a test report. Call for information concerning these services.
Unit of Measure

Specifications

Capacitance

N/A 10 nF

Capacitance Tolerance

N/A ±10%

Length

N/A 3.12 in79.2 mm

Width

N/A 2.06 in52.3 mm

Thickness

N/A 0.27 in6.9 mm

Dissipation Factor

N/A 0.005 Max. at 25°C, 1 kHZ

Dielectric Withstanding Voltage

N/A 12.5 kV rated 15 kV burn-in for 2 hours at 100°C 17.5 kV proof for 5 seconds
Standard/Non-Standard1 N/A Standard Part

Voltage Rating

N/A 12.5 kVDC

Cable Preparation

Insulation Resistance

N/A 25 MΩ*µF at125°C, need not exceed 1GΩ 4000 MΩ*µF at25°C, need not exceed 100GΩ
  • 1 Non-standard parts will have longer lead times and potentially higher pricing. Please contact Teledyne Reynolds Engineering department to determine feasibility for use in your application.