Contact us at: (310) 823-5491
The Deci-Arc tubes are for protection in circuits where high energy transients are anticipated and where size 18 AWG or larger wire sizes are used. They have a 20,000 ampere (8 x 20 usec waveshape) capability and may be used in combination with suitable series resistance for protection on both AC and DC power circuits. Capacitance of these tubes is less than 10pF and initial insulation resistance is greater than 10 ohms.

The spark gaps are available in DC breakdown voltage ranges from 230 to 10,000 volts. Units normally stocked are as follows. Other breakdown voltages available on request.

1 - 6 of 6 | Results Per Page | View | Unit of Measure
1 

Part Number

DC Breakdown Voltage at 100V/sec

Impulse Breakdown at 10kV/usec

Add To Cart/Request Quote
N/A 72 to 108 V N/A <1100 Request Quote
N/A 186 to 264 V N/A <1200 Request Quote
N/A 298 to 402 V N/A <1300 Request Quote
N/A 425 to 575 V N/A <1800 Request Quote
N/A 680 to 920 V N/A <2100 Request Quote
N/A 850 to 1150 V N/A <2200 Request Quote
1 - 6 of 6 | Results Per Page | View | Unit of Measure
1