Quiet Line is available with or without a silicone rubber coating. This continuous thin wall coating is applied over the FEP or PFA jacket and allows the user to achieve a superior dielectric bond when potting or encapsulating with a compatible silicone material.
Quiet Line is available either shielded or non-shielded with or without the silicone rubber coating. Six loss core diameters are offered providing a range of rated voltages and R.F. insertion loss characteristics. The configurations are shown with the attributes of each configuration.
Special configurations are available pending a review of your requirements by Reynolds engineering department personnel.
Operating Temperature
-55 to +125 ºC
Items |
/Asset/figure1.gif 178-8051 Quiet Line Type 1 |
/Asset/figure1.gif 178-8301 Quiet Line Type 1 |
/Asset/figure1.gif 178-8053 Quiet Line Type 1 |
/Asset/figure1.gif 178-8050 Quiet Line Type 1 |
/Asset/figure1.gif 178-8382 Quiet Line Type 1 |
|||||
Attenuation (480 MHZ) | N/A 11 dB/ft | N/A 15 dB/ft | N/A 21 dB/ft | N/A 21 dB/ft | N/A 15 dB/ft | |||||
Attenuation (2.4 GHZ) | N/A 90 dB/ft | N/A 60 dB/ft | N/A 140 dB/ft | N/A 130 dB/ft | N/A 90 dB/ft | |||||
Conductor Gauge | N/A 22 AWG | N/A 24 AWG | N/A 22 AWG | N/A 22 AWG | N/A 22 AWG | |||||
Conductor Strands | N/A 19/34 | N/A 19/36 | N/A 19/34 | N/A 19/34 | N/A 19/34 | |||||
Diameter | N/A 0.085 in2.1 mm | N/A 0.073 in1.8 mm | N/A 0.150 in3.8 mm | N/A 0.130 in3.3 mm | N/A 0.110 in2.7 mm | |||||
Overall Diameter | N/A 0.085 in | N/A 0.073 in | N/A 0.150 in | N/A 0.130 in | N/A 0.110 in | |||||
Insulator Material | N/A PFA | |||||||||
Braid Material | N/A Silver Plated Copper | |||||||||
Jacket Material | N/A FEP PFA | |||||||||
Voltage Stress Testing | N/A 100% test at 140% of rated voltage (room ambient) | |||||||||
Insertion Loss Testing | N/A 100% insertion loss verification performed on each extrusion lot. The swept frequency insertion loss technique is used within the specified frequency range per MIL-C-17F. Test specimens are shielded with a BNC termination. | |||||||||
Operating Temperature | N/A -55 to 125 ºC | |||||||||
Jacketed | N/A No | |||||||||
Silicone Coated | N/A No | |||||||||
Etched | N/A No | |||||||||
Default Color1 | N/A Natural | |||||||||
Conductor Plating | N/A Silver Plated | |||||||||
Conductor Material | N/A Copper | |||||||||
Construction Style |
N/A
1 |
|||||||||
Standard/Non-Standard2 | N/A Standard Part | |||||||||
Silicone Coated Part Number | N/A 178-8024 | N/A 178-8302 | N/A | N/A 178-8025 | N/A 178-8381 | |||||
Nomex ® Jacketed | N/A No | |||||||||
Twisted Pair | N/A No | |||||||||
Twisted Shielded Pair | N/A No | |||||||||
Voltage Rating | N/A 12 kVDC | N/A 15 kVDC | N/A 20 kVDC | N/A 20 kVDC | N/A 20 kVDC | |||||
|
1001 Knox Street, Torrance, California, 90502