Quiet Line is available with or without a silicone rubber coating. This continuous thin wall coating is applied over the FEP or PFA jacket and allows the user to achieve a superior dielectric bond when potting or encapsulating with a compatible silicone material.
Quiet Line is available either shielded or non-shielded with or without the silicone rubber coating. Six loss core diameters are offered providing a range of rated voltages and R.F. insertion loss characteristics. The configurations are shown with the attributes of each configuration.
Special configurations are available pending a review of your requirements by Reynolds engineering department personnel.
Operating Temperature
-55 to +125 ºC
Attenuation (480 MHZ) |
N/A 21 dB/ft |
Attenuation (2.4 GHZ) |
N/A 140 dB/ft |
Conductor Gauge |
N/A 22 AWG |
Conductor Strands |
N/A 19/34 |
Diameter |
N/A 0.160 in4.0 mm |
Overall Diameter |
N/A 0.160 in |
Insulator Material |
N/A FEP |
Braid Material |
N/A Silver Plated Copper |
Jacket Material |
N/A FEP PFA |
Voltage Stress Testing |
N/A 100% test at 140% of rated voltage (room ambient) |
Insertion Loss Testing |
N/A 100% insertion loss verification performed on each extrusion lot. The swept frequency insertion loss technique is used within the specified frequency range per MIL-C-17F. Test specimens are shielded with a BNC termination. |
Operating Temperature |
N/A -55 to 125 ºC |
Default Color1 | N/A Natural |
Conductor Plating |
N/A Tin Plated |
Conductor Material |
N/A Copper |
Construction Style |
N/A
2 |
Standard/Non-Standard2 | N/A Standard Part |
Voltage Rating |
N/A 20 kVDC |
1001 Knox Street, Torrance, California, 90502
Copyright © 2020 Teledyne Technologies Incorporated. All rights reserved.