Contact us at: (310) 823-5491
Series 600
A complete line of subminiature, coaxial, high voltage connectors. The Series 600 is rated at 5 kVDC for reduced atmospheric pressure operation over the temperature range of -55° thru 125°C. Various adapters are available on special order.

Series 600 SL
The 600 SL Series receptacles are rated for use only at Sea Level (up to 10,000 ft) atmospheric pressures, but they can be used at double the operating voltage (10 kVDC) of the 600 Series. The 600 SL Series receptacles mate with all 600 Series plugs and cable assemblies.

Series 610
The 610 Series has a larger coupling nut and threads than the 600 Series and is recommended for airborne applications or any application where numerous mating operations are required. 600 and 610 Series connectors are not interchangeable and can therefore be used for polarization to prevent cross mating in multiple circuit applications.
Series 600 and 610 cable assemblies effect an altitude seal through the use of internal seals. This design feature allows the mated assemblies to operate at altitudes up to 70,000 ft with no encapsulation within a temperature range of -55° to 125°C.

Series 610 SL
Similar to the 600 SL Series, the 610 SL Series receptacles are rated for use only at Sea Level (up to 10,000 ft) atmospheric pressures, but they can be used at double the operating voltage (10 kVDC) of the 610 Series. The 610 SL Series receptacles mate with all 610 Series plugs and cable assemblies.

Series 600 SQ "Space Qualified"
Series 600 SQ "Space Qualified" connectors are designed to operate over a long period of time in the hard vacuum of space. The operating voltage is 5 kVDC at a minimum vacuum of 10 millitorr to deep space.
Series 600 SQ connectors and cable assemblies are not interchangeable with Series 600 connectors or cable assemblies and should not be used in any application other than one with a minimum vacuum of 10 millitorr or in deep space.

Operating Temperature
-55º to 125 ºC

Voltage Rating
5 kVDC at 70,000 ft
10 kVDC at sea level (up to 10,000 ft)

Current Rating
5 Amps

NOTE: While plugs (kits) are available for customer-fabricated cable assemblies, Teledyne Reynolds highly recommends purchasing cable assemblies because of difficulties customers may experience in assembly and testing. Panel connectors require encapsulation at the junction of the terminal and the insulator.

Unit of Measure
Items
Image

600 Series Sealed, Recept-Plug-Recept T-Adapter (Non-standard)

Double-Ended, Shielded Hex Plug Cable Assemblies

600 Series Cable Assembly, Double-Ended Shielded, Hex Plug

Double-Ended, Shielded Knurled Plug Cable Assemblies

600 Series Cable Assembly, Double-Ended Shielded, Knurled Plug

178-7110-Plugs

600 Series Plug Kit, Shielded, Hex Coupling

167-3770 Plugs

600 Series Plug Kit, Shielded, Knurled Coupling
Series N/A 600
Voltage Rating N/A 5 kVDC
Altitude/Reduced Pressure Rating N/A 70,000 ft.
Assembly Type N/A "T" Adapter N/A Double-Ended Plug Cable Assembly N/A Double-Ended Plug Cable Assembly N/A Plug Bag Assembly N/A Plug Bag Assembly
Operating Temperature N/A -55 to 125 ºC
Test Voltage N/A 7.5 kVDC at 70,000 ft. (simulated) at ambient temperature
Coupling Nut Style N/A Knurled Coupling N/A Hex Coupling N/A Knurled Coupling N/A Hex Coupling N/A Knurled Coupling
Wire Type N/A N/A Shielded N/A Shielded N/A Shielded N/A Shielded
Shielded Cable N/A N/A Type "L" cable #167-2896 N/A Type "L" cable #167-2896 N/A Type "L" cable #167-2896 N/A Type "L" cable #167-2896
Mating Compatibility1 N/A Mates all Series 600 and 600 SL plugs and receptacles N/A Mates all Series 600 receptacles N/A Mates all Series 600 receptacles N/A Mates all Series 600 and 600-SL receptacles N/A Mates all Series 600 and 600-SL receptacles
Test Seal Installation/Removal Tool N/A
Insulator Material N/A Plastic
Lock Wire Holes in Coupling Nut N/A No N/A Yes N/A No N/A Yes N/A No
Coupling Nut Material N/A Brass N/A Brass Stainless Steel N/A Brass N/A Brass Stainless Steel N/A Brass
Contact Material N/A BeCu
Contact Finish N/A Gold
Coupling Nut Finish N/A Gold Gold Plated N/A Gold Plated Passivated N/A Gold Gold Plated N/A Gold Plated Passivated N/A Gold Gold Plated
Panel Mounting Style N/A
Mounting N/A
Panel Mounting Torque N/A
Mating Torque N/A
Contact Diameter N/A
Maximum Leak Rate (Helium)
N/A
Pressure Differential Rating N/A
Sealed Receptacle N/A No N/A N/A N/A N/A N/A N/A N/A
END #1 N/A N/A 178-7110 N/A 167-3770 N/A N/A
END #2 N/A N/A 178-7110 N/A 167-3770 N/A N/A
Standard/Non-Standard2 N/A Non-standard Part N/A Standard Part N/A Standard Part N/A Standard Part N/A Standard Part
Coupling Style N/A Threaded
Export Classification N/A TBD
RoHS Compliant N/A TBD
  • 1 It is highly recommended that gold plated, brass body receptacles only be mated with gold plated, brass body, knurled plugs. Stainless steel parts should not be mated with gold plated, brass body parts.
  • 2 Non-standard parts will have longer lead times and potentially higher pricing. Please contact Teledyne Reynolds Engineering department to determine feasibility for use in your application.