Series 610
The 610 Series has a larger coupling nut and threads than the 600 Series and is recommended for airborne applications or any application where numerous mating operations are required. 600 and 610 Series connectors are not interchangeable and can therefore be used for polarization to prevent cross mating in multiple circuit applications.
Series 600 and 610 cable assemblies effect an altitude seal through the use of internal seals. This design feature allows the mated assemblies to operate at altitudes up to 70,000 ft with no encapsulation within a temperature range of -55° to 125°C.
Series 610 SL
Similar to the 600 SL Series, the 610 SL Series receptacles are rated for use only at Sea Level (up to 10,000 ft) atmospheric pressures, but they can be used at double the operating voltage (10 kVDC) of the 610 Series. The 610 SL Series receptacles mate with all 610 Series plugs and cable assemblies.
Series 600 SQ "Space Qualified"
Series 600 SQ "Space Qualified" connectors are designed to operate over a long period of time in the hard vacuum of space. The operating voltage is 5 kVDC at a minimum vacuum of 10 millitorr to deep space.
Series 600 SQ connectors and cable assemblies are not interchangeable with Series 600 connectors or cable assemblies and should not be used in any application other than one with a minimum vacuum of 10 millitorr or in deep space.
Operating Temperature
-55º to 125 ºC
Voltage Rating
5 kVDC at 70,000 ft
10 kVDC at sea level (up to 10,000 ft)
Current Rating
5 Amps
NOTE: While plugs (kits) are available for customer-fabricated cable assemblies, Teledyne Reynolds highly recommends purchasing cable assemblies because of difficulties customers may experience in assembly and testing. Panel connectors require encapsulation at the junction of the terminal and the insulator.
Items |
/ImgCustom/1002/placeholder_notavailable.gif 167-3888 600 Series Sealed, Recept-Plug-Recept T-Adapter (Non-standard) |
/Asset/a1813.jpg 178-7113 600 Series Cable Assembly, Double-Ended Shielded, Hex Plug |
/Asset/a1814.jpg 167-3306 600 Series Cable Assembly, Double-Ended Shielded, Knurled Plug |
/Asset/178-7110-Plugs.JPG 178-7110 600 Series Plug Kit, Shielded, Hex Coupling |
/Asset/a1802.jpg 167-3770 600 Series Plug Kit, Shielded, Knurled Coupling |
|||||
Series | N/A 600 | |||||||||
Voltage Rating | N/A 5 kVDC | |||||||||
Altitude/Reduced Pressure Rating | N/A 70,000 ft. | |||||||||
Assembly Type | N/A "T" Adapter | N/A Double-Ended Plug Cable Assembly | N/A Double-Ended Plug Cable Assembly | N/A Plug Bag Assembly | N/A Plug Bag Assembly | |||||
Operating Temperature | N/A -55 to 125 ºC | |||||||||
Test Voltage | N/A 7.5 kVDC at 70,000 ft. (simulated) at ambient temperature | |||||||||
Coupling Nut Style | N/A Knurled Coupling | N/A Hex Coupling | N/A Knurled Coupling | N/A Hex Coupling | N/A Knurled Coupling | |||||
Wire Type | N/A | N/A Shielded | N/A Shielded | N/A Shielded | N/A Shielded | |||||
Shielded Cable | N/A | N/A Type "L" cable #167-2896 | N/A Type "L" cable #167-2896 | N/A Type "L" cable #167-2896 | N/A Type "L" cable #167-2896 | |||||
Mating Compatibility1 | N/A Mates all Series 600 and 600 SL plugs and receptacles | N/A Mates all Series 600 receptacles | N/A Mates all Series 600 receptacles | N/A Mates all Series 600 and 600-SL receptacles | N/A Mates all Series 600 and 600-SL receptacles | |||||
Test Seal Installation/Removal Tool | N/A | |||||||||
Insulator Material | N/A Plastic | |||||||||
Lock Wire Holes in Coupling Nut | N/A No | N/A Yes | N/A No | N/A Yes | N/A No | |||||
Coupling Nut Material | N/A Brass | N/A Brass Stainless Steel | N/A Brass | N/A Brass Stainless Steel | N/A Brass | |||||
Contact Material | N/A BeCu | |||||||||
Contact Finish | N/A Gold | |||||||||
Coupling Nut Finish | N/A Gold Gold Plated | N/A Gold Plated Passivated | N/A Gold Gold Plated | N/A Gold Plated Passivated | N/A Gold Gold Plated | |||||
Panel Mounting Style | N/A | |||||||||
Mounting | N/A | |||||||||
Panel Mounting Torque | N/A | |||||||||
Mating Torque | N/A | |||||||||
Contact Diameter | N/A | |||||||||
Maximum Leak Rate (Helium) |
N/A | |||||||||
Pressure Differential Rating | N/A | |||||||||
Sealed Receptacle | N/A No | N/A N/A | N/A N/A | N/A | N/A N/A | |||||
END #1 | N/A | N/A 178-7110 | N/A 167-3770 | N/A | N/A | |||||
END #2 | N/A | N/A 178-7110 | N/A 167-3770 | N/A | N/A | |||||
Standard/Non-Standard2 | N/A Non-standard Part | N/A Standard Part | N/A Standard Part | N/A Standard Part | N/A Standard Part | |||||
Coupling Style | N/A Threaded | |||||||||
Export Classification | N/A TBD | |||||||||
RoHS Compliant | N/A TBD | |||||||||
|