Contact us at: (310) 823-5491
Extruded FEP insulated high voltage wire and cable offers exceptional dielectric strength without the disadvantages common to equally rated silicone rubber insulated cables. As a result, cable assemblies or cable bundles are of smaller diameter and therefore take up substantially less volume and have a smaller bend radius which allows the designer to better utilize the space within the system. It has good corona inception qualities and its construction gives it excellent durability and resistance to dielectric/cooling fluid degradation.

While difficult to bond to, with the use of Reynolds proper abrading and coating preparations an excellent silastic bond is possible. Additionally, FEP insulation, being a harder material than silicone rubber, is not prone to pin-holing and high voltage punch-thru when the cable surface is abraded or when strands break during in-field service. FEP is also more resistant to damage when making contact with sharp edges.

FEP cable should not only be considered for use in cable assemblies, but as high voltage hook up wire within encapsulated high voltage power supplies, TWTs and transformers.

Low DC corona inception, particularly after numerous temperature cycles, is another advantage of FEP over silicone cables. Teflon tape wrapped cable, which is similar to FEP in dielectric strength and corona inception, is difficult to bond to because of its multiple spiral cross section, irregular surface and variations in diameter

Note: Pre-conditioning of FEP wire or cable is recommended because FEP insulation will shrink when exposed to temperature cycling. Pre-conditioning should be conducted in an air circulating oven at 204°C (400°F) for one hour. Pre-conditioning should only be performed on cut lengths prior to stripping and any termination procedure. No attempt should be made to condition wire or cable in bulk form or while spooled.

Operating Temperature
-55 to +125 ºC
Unit of Measure

Specifications

Conductor Gauge

N/A 22 AWG

Conductor Strands

N/A 19/34

Insulator Material

N/A FEP

Conductor Diameter

N/A 0.031 in0.080 in0.80 mm

Diameter Over Insulation

N/A 0.080 in2.00 mm

Overall Diameter

N/A 0.080 in
Default Color1 N/A Natural

Operating Temperature

N/A -55 to 125 ºC

Conductor Plating

N/A Silver Plated

Conductor Material

N/A Copper
Standard/Non-Standard2 N/A Standard Part

Voltage Rating

N/A 22 kVDC

Cable / Wire Properties

Jacketed

N/A No

Silicone Coated

N/A No

Nomex ® Jacketed Etched Part Number

N/A 178-9639

Twisted Pair

N/A No

Twisted Shielded Pair

N/A No

Alternate Cable Part Number Equivalents

Silicone Coated Part Number

N/A 178-9036

Etched Part Number

N/A 178-9035
  • 1 Other colors available upon request.
  • 2 Non-standard parts will have longer lead times and potentially higher pricing. Please contact Teledyne Reynolds Engineering department to determine feasibility for use in your application.